Mitigation of radon in the air is accomplished through ventilation either collected below a concrete floor slab or a membrane on the ground or by increasing the air changes per.
Radon mitigation plastic sheet.
Radon mitigation fans draw not just soil gas from the ground but also indoor air from the house through the concrete slab.
Moreover mitigation if often cheaper than testing.
Polyethylene or a vapor retarder on top of the gravel to prevent the soil gases from entering the house.
Radon is a significant contributor to environmental radioactivity.
If a problem exists go with depressurization.
Remove radon gas using suction suction systems work by creating negative air pressure in an existing sump pump pit a freshly dug gravel pit under your concrete floor or by placing a plastic sheet over the soil in your crawl space and sucking air from under the plastic.
Plastic sheeting or vapor retarder.
This may cause back drafting and spillage of combustion gases from the furnace water heater or fireplace in modern tight houses.
Also we wrap the plastic up any wall at least 12 inches and seal it to the wall with either spray adhesive or urethane caulk.
It s similar to the active system already described with the notable difference being that instead of allowing the gas to become trapped or collected under a basement slab of concrete before venting in this scenario your pre vent collection area is the plastic sheet membrane.
Radon mitigation system components.
90w and piping for 200 in my existing slab to mitigate a radon problem.
I installed a radon fan fantech hp2190.
As with an asd system the exhaust of the fan must vent above the roof line.
Homes with crawl spaces might instead cover the earth floor with a high density plastic sheet and use a vent pipe and a fan to force the radon gas outside.
Newer construction may rely on passive mitigation where pipes are installed in the foundation creating a natural vacuum and directing the radon out of the house without use of a fan.
A radon pipe penetrates the plastic sheeting pulls the soil gas from the crawl space and vents it outside.
Radon mitigation is any process used to reduce radon gas concentrations in the breathing zones of occupied buildings or radon from water supplies.
The sheeting also keeps the concrete from clogging the gravel layer when the slab is poured.
Place heavy duty plastic sheeting 6 mil.
Sub membrane used in crawl spaces a plastic sheet covers exposed dirt on the floor extends up onto the wall and is sealed.
Installing a co alarm with fan based radon mitigation is a good idea.